TM
9-2350-222-10-3
TROUBLESHOOTING - Continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
s
37.2 SEARCHLIGHT FAILS TO OPERATE OR DOES NOT OPERATE
PROPERLY - Continued
a. If either fuse is defective (wire broken), replace with good fuse from
spare lamp box (motor fuse is 1 amp, 125v, auxiliary B+ fuse is 2
amp, 250v.).
b. If fuses are not defective, or if spare fuses are not available, notify
organizational maintenance.
38. LACK OF AIR, GAS-PARTICULATE FILTER UNIT
s
Make sure spring clip (A) has been lifted from air intake opening on
Step 1.
filter unit (B).
If not, lift from air intake opening.
Step 2. Check electrical connector (C) at precleaned and filter unit.
If connector is loose, tighten.
Step 3. Check if precleaned and filter unit motor is operating by listening
for motor noise.
If motor is not running, notify organizational maintenance.
TA252954