TM 9-2350-222-10-3
MAINTAIN TURRET (BALANCE AND ADJUST EQUILIBRATOR
ACCUMULATOR PRESSURE) - Continued
5. Turn handle (C) one turn clockwise to close charging valve.
NOTE
If pressure gage (A) reads
above 1800 psi, equilibrator
system is high. Continue with
step 6. If gage reads below
1800 psi; go to step 7.
6. With main gun fully elevated
watch pressure gage (A),
Turning handle (B) one turn
counterclockwise, open drain
valve. When pressure gage (A)
reads 1700-1800 psi, turn
handle (B) clockwise,
closing drain valve.
NOTE
After equilibrator accumulator has
been balanced and adjusted pressure
gage (A) should hold above 1500 psi. If
pressure gage (A) drops below 1500
psi, add hydraulic fluid to hydraulic
reservoir (pages 3-262). Notify organi-
zational maintenance you had to add
hydraulic fluid as soon as possible.
7. Elevate and depress main gun (page 2-502) several times to make
sure main gun operates smoothly. If main gun does not operate
smoothly, notify organizational maintenance.
TA133091