TM 9-4110-254-14
5-36. COMPRESSOR B1 TESTING, REPAIR, AND REPLACEMENT.
This task covers:
a. Testing
b. Removal
c. Disassembly
d. Assembly
e. Installation
INITIAL SETUP
Materials/Parts-
Materials / Parts
Lock Washers (4)
Seal
Locknut (4)
Marker tags (15)
Service Valve Gasket (Suction)
Anti-Seize Tape
Service Valve Gasket (Discharge)
Lubricating Oil
Cylinder Head Gasket
Equipment Conditions:
Valve Plate Gasket
Front top door open
Both side doors open
Sight Glass
Lock Washers (2)
General Safety Instructions.
Fused Cluster Terminal
WARNING
Fused Cluster Seal
Compressor lubricating oil used m this
refrigeration system is caustic. Wear gloves
Terminal Mounting Plate Gasket
and a face protector or safety glasses m any
situation where skin or eye contact is
Oil Pump Gasket
possible. If oil does contact skin, wash with
soap and water.
a. Service.
(1)
Check oil level through sight glass (1). If oil level is not within best operating range, discharge
CAUTION
Use only specified oil Compressor damage can result
NOTE
The oil fill plug cannot be purchased separately from the compressor.
Care must be taken so it does not get lost or damaged.
(2)
Remove oil fill plug (2) then add or remove lubricating oil as necessary
(3)
Wrap anti-seize tape around oil fill plug (2) threads and install oil fill plug
5-75