TM 9-4110-255-14
4-57. VOLTAGE REGULATOR REPLACEMENT.
This task covers:
a. Removal
b. Installation
INITIAL SETUP
Materials/Parts:
Equipment Conditions:
Lock Washers (2)
Refrigeration unit shut down (para 2-7) and batery
Left side door open.
a. Removal.
(1) Disconnect connector (1) from voltage regulator (2).
Figure 4-51. Voltage Regulator
(2) Remove two bolts (3), lock washers (4), flat washers (5), and voltage regulator (2). Discard lock washers.
b. Installation.
(1) Install voltage regulator (2), two flat washer (5), new lock washers (4), and bolts (3).
(2) If connection (1) or any wire leads (6) are damaged, pul cap (7) back and replace or repair as necessary
l
(3) If cap (7) was pulled back, slip back over connection (1) then plug connection onto voltage regulator (2).
NOTE
FOLLOW-ON MAINTENANCE:
Close right side door.
Connect battery (para 4-35) and put unit back into service.
4-134