TM 9-4110-256-14
Table 4-1. Preventive Maintenance Checks and Services for Model F10000RE
Location
Item
Interval
Item to
Procedure
Not Fully Mission
No.
Check/Service
Capable If:
15
Semi-
Heat
Inspect the heat exchanger for dents or evidence
Heat exchanger is dented
Annually
Exchanger
of refrigerant leak. If damaged or evidence of
or evidence of leak is
leaking found, notify direct support maintenance
found.
to replace it.
16
Semi-
Expansion
a. Inspect the expansion valve for evidence of
Evidence of leak is found,
Annually
Valve
refrigerant leak. If evidence or leak is
sensing bulb is loose on
found, notify direct support maintenance to
tubing, or capillary line is
replace it.
kinked or broken.
b. Inspect the sensing bulb capillary line for
cracks, kinks, or breaks. If damaged, notify
direct support maintenance to replace the
expansion valve.
c. Check that the sensing bulb mounting
hardware is secure and the bulb is in
contact with the tubing. Tighten the
mounting hardware if loose.
Refrigeration
Unit Interior
17
Annually
Wires,
Inspect for frayed or broken wire leads. If
Wire lead frayed or
Cables, and
damaged, repair or replace as needed
broken.
Harnesses
4-19