TM 9-4110-256-14
Table 4-1. Preventive Maintenance Checks and Services for Model F10000RE
Location
Item
Interval
Item to
Procedure
Not Fully Mission
No.
Check/Service
Capable If:
12
Semi-
Repeat Cycle
a. Check for loose or missing mounting socket
Mounting hardware or
Annually
Timer
hardware and wire terminals. Tighten or
wire terminals are loose.
Case is damaged.
b. Inspect case and mounting socket for cracks,
breaks, or evidence of overheating.
c. Check and adjust the timer controls if
13
Semi-
Remote Bulb
a. Remove cover and check for loose or missing
Sensing bulb capillary line
Annually
Thermostat
mounting hardware and wire terminals.
is kinked or broken.
Mounting hardware or
wire terminals are loose.
b. Inspect for kinked or broken sensing bulb
capillary line. If damaged, replace remote
Refrigeration
Unit Exterior
NOTE
removed for the following semi-annual
PMCS.
14
Semi-
Defrost
Wire lead frayed or
Annually
Temperature
broken. Defrost
Switch
temperature switch loose
b. Inspect for frayed or broken wire leads. If
on tubing.
damaged, repair or replace as needed
c. Check that the mounting hardware is
secure and the switch is in contact with the
tubing. Tighten the mounting hardware if
loose
4-18