TM 9-4110-256-14
Table 4-1. Preventive Maintenance Checks and Services for Model F10000RE
Location
Item
Interval
Item to
Procedure
Not Fully Mission
No.
Check/Service
Capable If:
Refrigeration
Unit Interior
7
Semi-
AC Motor
Inspect AC motor for evidence of overheating in
Evidence of overheating is
Annually
the form of discolored or blistered paint. Check
found. Shaft is loose,
for loose or missing mounting hardware and
mounting hardware is
loose shaft. If evidence of overheating is
loose or missing.
observed or the shaft is loose, replace motor
missing, tighten or replace as necessary
Control Box
Interior
NOTE
The control box must be open for all
interior control box PMCS.
8
Semi-
Fuse
Wire lead or fuse clip
Annually
loose. Fuse link is broken
or fuse case is discolored.
b. Check for loose or missing fuse block
mounting hardware, loose wire leads, and
loose fuse block clips. If mounting
hardware or leads are loose, tighten or
block clips are loose, replace fuse block
c. Check fuse for broken link or discoloration
of case. Replace fuse if link is broken or
4-16