TM 9-4110-256-14
Table 4-1. Preventive Maintenance Checks and Services for Model F10000RE
Location
Item
Interval
Item to
Procedure
Not Fully Mission
No.
Check/Service
Capable If:
Refrigeration
Unit Interior
5
Monthly
Flange
Service the flange bearings by lubricating them
a. Wipe grease fitting with a clean rag.
b. Pump grease gun handle until a flow of
clean grease (MIL-G-23549) comes out
nozzle.
c. Attach grease gun nozzle to grease fitting
and pump handle until grease just begins
coming out around bearing.
d. Remove grease gun nozzle and wipe away
excess grease with a clean rag.
6
Monthly
Evaporator
Fan is cracked, torn, or
Fan
loose.
Inspect for loose connection to fan drive
shaft. If loose, tighten to shaft. If
4-15