TM 9-4110-256-14
5-19.
RECEIVER REPLACEMENT.
This task covers:
a. Removal
b. Installation
INITIAL SETUP
Equipment Conditions:
Materials/Parts:
Self Locking Nuts (2)
Anti-Seize Tape
General Safety Instructions:
Lubricating Oil
WARNING
this refrigeration system is caustic.
Wear gloves and a face protector or
safety glasses in any situation where
skin or eye contact is possible. If oil
does contact skin, wash with soap
and water.
a.
Removal.
(1)
Remove two isolation valve caps (1).
(2)
Loosen two flare nuts (2) and move copper tubing (3) away from isolation valve (4) being careful not to
bend or kink tubing.
Figure 5-15. Receiver
5-39