TM 9-4110-258-13
b. Installation.
(1) Install pressure regulator valve (7) and two bushings (6) then braze the two bushings and fittings (5) onto
(2) Install clamp (4), new lock washer (3), and bolt (2).
(3) Install insulation (1) and secure with insulation tape as necessary.
NOTE
FOLLOW-ON MAINTENANCE:
Close left side door.
5.20
PRESSURE REGULATOR VALVE (CRANKCASE) REPLACEMENT
This task covers:
a. Removal
b. Installation
INITIAL SETUP
Materials/Parts
Equipment Conditions:
Lock Washers
Insulation Tape
Right side door open.
a. Removal.
(1) Remove insulation (1) as necessary.
(2) Remove bolt (2), lock washer (3), and clamp (4). Discard lock washer.
(3) De-braze two fittings (5) and remove pressure regulator valve (6) (para 5.10).
5-39