a. Removal.
(1) Remove insulation (1) as necessary.
(2) De-braze two fittings (2) (para 5.10) and remove metal hose assembly (3).
Figure 5-17. Metal Hose Assembly (Discharge)
b. Installation.
(1) Install metal hose assembly (3) and braze two fittings (2) (para 5.10).
(2) Install insulation (1) and secure with insulation tape as necessary.
NOTE
FOLLOW-ON MAINTENANCE:
Close right side door.
5-43