TM9-4120-370-14
TO35E9-229-1
4-42. BLOCK-OFF ASSEMBLY - Continued.
(4) Install lower front panel.
Follow-on procedure: Connect power.
4-43. WIRING HARNESSES
Preliminary procedures: 1. Remove top panel. (See para 424.)
lnspection/Test
a.
(1) Check to be sure that power has been disconnected.
(2) Check connectors for general condition and loose, broken, or missing contacts. Replace damaged
connectors.
(3) Check individual wires for loose solder connections, loose terminal lug connections, cut or frayed
insulation, and cut or broken wires.
(4) See wiring diagram (Figure 4-20) and continuity test individual wires. Repair or replace wires with no conti-
nuity.
b. Repair
(2) See Table 4-3 (Wire List) for wire lengths and terminal/connector information.
Removal/Installation. See Figure 459 for removal/installation information.
c.
Follow-on procedures: 1. Install front panel. (See para 4-25.)