TM9-4120-370-14
TO35E9-229-1
Compressed air used for cleaning purposes will not exceed 30 psi (2.1 kg/cm2).
Do not direct compressed air against the skin. Use goggles or full face shield.
CAUTION
Do not use steam to clean coil.
b. Cleaning. Clean coil with a soft bristle brush, vacuum cleaner and brush attachment, or use compressed air
at 30 psi or less from the inside of the unit to blow the dirt out. Take care to avoid fin damage. When using com-
pressed air, wear safety glasses or goggles. Dirt can be blown into your eyes,
Repair/Replacement. Should a leak or major damage be evident, refer to direct support maintenance.
c.
Follow-on procedure,
Preliminary procedure:
2. Remove condenser discharge air deflector door on F36T-2SA and F36T4-2SB. (See para
Inspection of installed coil
a.
(1) Check to be sure that power is disconnected,
(2) Check for accumulated dirt. Clean if an accumulation of dirt is evident.
(3) Check fins for dents, bent edges, or anycondition that would block or distort air flow. Straighten all damaged
fins with a plastic fin comb.