TM 9-4120-371-14
Place ground lug on reset cable shaft.
Place lock washer on reset cable shaft (Effective for Keco Model F18T-2S Serial No. 81489
through 81533.)
Insert reset cable shaft through hole in box.
Place flat washer and sealing nut on to end of reset cable and tighten finger tight.
Using wrench, tighten nut on back side of box.
Screw knob onto end of shaft
Tighten small nut.
(4) Slip ground stud through panel and secure with two nuts, two flat washers, and one lock washer.
(Effective for Keco Model F18T-2S Serial No's. 82760 and higher, Keco Model F18T-2SA, and A.R.E. Model
CVP-20-5/6-08.)
(5) Using screwdriver, secure back panel with twenty-one flat head screws and twenty-four pan head
screws and flat washers.
(6) Using screwdriver, secure refrigerant sight glass bracket with two screws, packing with retainers,
and lock washers.
Follow-on procedures: 1. Install top panel. (See para 4-29.)
4. Install access (service valve) cover. (See para 4-21.)
a. Removal
(1) Using screwdriver, loosen six captive turnlock stud fasteners in intake grille assembly
(2) Remove grille.