TM 9-4120-371-14
TABLE 4-3. WIRE LIST (cont)
AWG
LENGTH
TERMINATION
TERMINATION
Wire
Size
IN.
FROM
TO
TERMINAL TYPE
CM
TERMINAL TYPE
WIRING HARNESS P2-P11
10
76.2
30.0
P2-A
MS3106R22-22S
P11-A
MS3106R22-22P
10
76.2
P2-B
MS3106R22-22S
P11-B
MS3106R22-22P
30.0
10
76.2
P2-C
MS3106R22-22P
30.0
MS3106R22-22S
P11-C
10
76.2
P2-D
MS3106R22-22P
30.0
MS3106R22-22S
P11-D
WIRING HARNESS J2
7.0
17.8
MS25036-112
10
TB11
J2-A
MS3102R22-22P
7.0
17.8
10
MS25036-112
J2-B
MS3102R22-22P
TB1-2
10
20.3
8.0
MS3102R22-22P
TB1-3
MS25036-112
J2-C
10
12.7
MS25036-112
5.0
MS3102R22-27P
J2-D
E1
WIRING HARNESS J8
16
35.0
88.9
MS3100R145-6P
HR1-A
MS25036-108
J8-A
16
J8-B
MS3100R14S-6P
HR2-A
MS25036-108
32.0
81.1
16
73.2
29.0
MS25036-108
J8-C
MS3100R14S-6P
HR3-A
16
27,0
68.6
MS3100R14S-6P
HR4-A
MS25036-108
J8-E
16
25.0
63.5
MS3100R14S-6P
MS25036-108
J6-F
HR5-A
16
21.0
53.3
MS25036-108
J8-D
M53100R14S-6P
HR6-A
43.2
HR1-B
16
17.0
MS25036-108
HR6-B
MS25036-108
HR2-B
16
10.0
25.4
MS25036-108
HR5-B
MS25036-108
HR3-B
16
12.7
MS25036-108
HR4-B
MS25036-108
5.0
GROUND CABLES
12
*FR-GND
E4
MS25036-157
33.0
83.8
MS25036-157
106.7
12
42.0
MS25036-157
MS25036-157
*E4
E3
*Effective for A.R.E. Model CVP-20-5/6-08 Only.
Disconnect input power to air conditioner before performing any internal
maintenance. Voltages used can KILL. Shutting unit off at control panel does
not disconnect unit power.
Preliminary procedures: Turn unit power off at power source. If there is a chance that it will be turned on, also
disconnect power cable to air conditioner.
NOTE
a. Removal. (If control panel is remote mounted, see facility or shelter manual.)
(1) Using screwdriver, loosen two captive panel fastener screws in lower front panel.