TM 9-4120-371-14
a. Inspection
(1)
Check for broken welds, badly bent or dented parts, and cracked or broken parts.
(2)
Check that plate nuts and blind nuts are in place and secure.
Refer repairs to general support maintenance.
(3)
(4) Check that insulation is not loose, missing, burnt, or otherwise damaged. Replace if missing or
damaged. Reglue if loose.
b. Insulation/Removal
NOTE
Prior to removal of old insulation, cut the new replacement material to size using the
old item as a sample.
(1)
Remove as much old insulation material as possible, by pulling or scraping it away from the metal
surface.
WARNING
Acetone and methylethyl ketone (MEK) are flammable, and their vapors can be
explosive. Repeated or prolonged skin contact or inhalation of vapors can be toxic
Use a well ventilated area, wear gloves, and keep away from sparks or flame.
(2)
Soften and remove old adhesive and insulation residue, using acetone or methyl-ethyl ketone
(MEK) and a stiff brush.
c. Installation
(1)
Cut to size.
Be sure that the surface to which the insulation is to be applied is clean and free of paint and old
(2)
adhesive material.
(3) Coat the mating surfaces of the metal and the insulation with adhesive (item 2, Appendix E). Let
both surfaces air dry until the adhesive is tacky, but will not stick to the fingers.
(4)
Starting with an end, carefully attach the insulation to the metal. Press into firm contact all over.