TM 9-4120-378-14
4.21 CONDENSER AIR DISCHARGE LOUVER AND LINKAGE-SERVICE/RE PLACE/ADJUST. This task
covers removal, disassembly, repair and clean, assembly, installation and adjustment.
Equipment Conditions:
Material/Part
Remarks
Action
Location/Item
Disconnect air conditioner power input
connector before doing maintenance
work on electrical system.
Condenser
Guard
Remove condenser guard (14) by removing eight
Removal
screws(16) and eight Iockwashers (15),
Condenser
Louver
a.
Loosen post screw (1).
Removal
Remove outer sheath retaining nut (2) from con-
b.
trol cable sheath (3).
c.
Pull end of wire (4) from mechanical post (5),
Remove seven screws (6) and seven lockwash-
d.
ers (7) securing condenser louver assembly (8)
to housing.
e.
housing.
Condenser
Louver
Remove five push nuts (9).
a.
disassembly
Remove two screws (1 0).
b.