TM 9-4120-378-14
LOUVERS-REPLACE. This task covers removal and installation.
5.13
Action
Remarks
Location/Item
Disconnect air conditioner power input con-
nector before doing maintenance work on
electrical system.
Louver
a . Remove eight screws (1) and eight Iockwashers (2) secur-
Removal
ing louver (3) to housing.
Remove louver (3).
b.
Remove evaporator air inlet filter (4) from filter clip (5).
c.
Evaporator
Outlet Louver
a. Remove six screws (6) and six Iockwashers (7) securing
Removal
louver (8) to housing.
b. Remove louver (8).