TM 9-4120-388-14
4-30. FILTER (RADIO FREQUENCY) MOUNTING PLATE.
This task consists of:
a. Removal
b. Inspection
c. Installation
INITIAL SET-UP:
Equipment Condition:
Turn off power.
Disconnect input power to the air conditioner before performing any internal
maintenance. Voltages used can KILL Shutting the unit off at the control paneI
does not disconnect unit power.
a.
Removal.
(1) Remove eight outermost screws from filter mounting plate.
(2) Slip plate and filter out and support filter.
(3) Remove six screws from mounting plate and filter.
(4) Remove mounting plate.
b. Inspection.
(1) Be sure that plate is not bent, cracked, or punctured.
(2) Notify your supervisor if damaged.
Installation.
c.
(1) Secure radio frequency filter to mounting plate with six screws.
(2) Secure mounting plate to casing with eight screws.
(3) Connect power.