TM 9-4120-388-14
4-33. CONDITIONED AIR FlLTER.
This task consists of:
a. Removal
b. Cleaning
c. Inspection
d. Installation
INITIAL SET-UP:
Condition:
Turn off power.
Disconnect input power to the air conditioner before performing any internal
maintenance. Voltages used can KILL Shutting the unit off at the control panel
does not disconnect unit power.
a.
Removal.
(1) Loosen six captive turnlock stud fasteners in intake grille assembly.
(2) Remove grille.
(3) Loosen two captive turnlock stud fasteners in filter retainer.
(4) Remove retainer and filter.
b . Cleaning.
(1)
Wash filter in a mild detergent and water solution.
(2)
Rinse thoroughly in dean water.
(3)
Shake out excess water prior to installation.
4-62