TM9-4120-398-14
This task covers: R e p l a c e m e n t
INITIAL SETUP
Tools
Equipment Conditions
Tool kit, refrigeration SVC
Riveter, blind, hand
Power OFF
General Safety Instructions
Materials/Parts
WARNING
Dry cleaning solvent (Federal Specification
PD-680) used to clean parts is
potentially dangerous to personnel and
property.
Do not usc near open flame or excessive heat.
Flash point of solvent is 100 F to 138 F
(38 C to 59 C).
Replacement
Adhesive mounted.
a.
WARNINGS
Dry cleaning solvent (Federal Specification PD-680) used to clean parts is potentially dangerous
to personnel and property. Do not use near open flame or excessive heat. Flash point of solvent is
100 F to 138F (38 C to 59 C).
mounting surface.
(2) Apply a thin coat of adhesive (item 1 Appendix E) to the information plate and mounting surface. Allow
adhesive to dry until tacky. Apply the information plate to mounting surface and press firmly to assure an even bond.
areas around the information plate, being careful not to allow solvent to flow undeneath the information plate.
(4-19 blank)/4-20