TM 9-4120-398-14
5-20. SIGHT LIQUID INDICATOR
This task covers:
Replacement
INITIAL SETUP
Tool kit, refrigeration SVC
Power OFF
System discharged
General Safety Instructions
WARNING
Rags
Voltages used can kill. Always
Brazing Alloy
disconnect power cord to air conditioner
before performing any internal
maintenance. Shutting unit off at its
control panel does not disconnect
unit power.
Filter drier
Refrigerant -22
Death or serious injury may result if personnel fail to observe safety precautions. Use great care to
avoid contact with liquid refrigerant or refrigerant gas being discharged under pressure. Sudden and
irreversible tissue damage can result from freezing. Wear thermal protective gloves and a face
protector or goggles in any situation where skin-eye contact is possible.
Prevent contact of refrigerant gas with flame or hot surfaces. Heat causes refrigerant to break down and form
carbonyl chloride (phosgene), a highly poisonous and corrosive gas.
a. Removal.
(1) Remove two screws (1), four washers (2), two Iockwashers (3), and nuts (4) securing gasket (5) and bracket
(6) to frame.
(3) Remove liquid sight indicator (7).
(5-51 blank)/5-52