TM 9-4120-398-14
5-20. SIGHT LIQUID INDICATOR (cont)
b. Installation.
NOTE
Do not disassemble liquid sight indicator.
(1) Position liquid sight indicator (7) on tubing.
(3) Install two screws (1), four washers (2), two Iockwashers (3), and two nuts (4) to secure gasket (5) and bracket
(6) to frame.
(6) Leak test all newly connected joints and those in the repair area. (See paragraph 5-8.)