TM 9-4120-403-14
(3) A good capacitor will be shown by meter quickly registering high resistance, then slowly backing off to zero
resistance.
(4) If meter displays high resistance and remains there, the capacitor is internally shorted and must be
replaced.
(5) If the meter does not show any resistance, the capacitor is open and must be replaced.
Removal
(1) Remove nut and data plate from solenoid valve L1.
(2) Remove LI coil assembly and set aside.
(3) Tag and disconnect wire leads on capacitor (C2).
(4) Remove four screws in casing that secure capacitor bracket.
(5) Remove bracket.
(6) Remove two screws and locknuts that secure retaining strap to bracket.
(7) Remove strap.
4-129