TM 9-4120-411-14
4.52 COVER RETAINING ROD REPLACEMENT - CONTINUED.
(3) Remove nut (1), lock washer (2), flat washer (3), cover retaining rod (4), flat washer (5), lock washer (6), and nut
(7). Discard lock washers.
Figure 4-51. Cover Retaining Rod.
(1) Install nut (7), new lock washer (6), and flat washer (5) onto cover retaining rod (4). Install cover retaining rod and
secure with flat washer (3), new lock washer (2), and nut (1). Place cover retaining rod in storage position and be
4.53 END RAIL REPLACEMENT.
THIS TASK COVERS:
a. Removal
b. Installation
INITIAL SETUP:
Tools
Materials/Parts
General Mechanics Tool Kit
Lock Washers (qty 3)
WARNING
Rotating parts and lethal voltage levels are used in operating the FDECU. Be sure
power source is disconnected. Injury or death can occur if connected to power
source.
(1) Shutdown the FDECU per paragraph 2.4 and disconnect it from power source.
4-122