TM 9-4910-387-14-1
4-15. RH ACCUMULATOR ASSEMBLY-MAINTENANCE INSTRUCTIONS (cont)
INSTALLATION
2
PIVOT BLOCK (4).
a.
Position on plate (5) and strap (6).
b.
Install two washers (7) and two
screws (8).
1
SIX HOSES (1) WITH SIX MALE
HOSE FITTINGS (2). Put through
plate (3).
CAUTION
3
SIX HOSES (1) WITH SIX MALE
Be careful when using slip
HOSE FITTINGS (2). Install on ac-
Joint pliers so no damage
cumulator assembly (9) using 7/16-in.
to hoses occurs. Apply
open end wrench (10) and slip joint
only enough pressure to
pliers (11).
prevent hoses from
slipping.
4-48