TM 9-4910-387-14-1
4-16. ACCUMULATOR ASSEMBLY-MAINTENANCE INSTRUCTIONS (cont )
REASSEMBLY
INSTALLATION
CAUTION
1
MOUNTING BAR (1). Position on ac-
Be careful when using slip
cumulator can assemblies (2).
joint pliers so no damage
to hoses occurs. Apply on-
2
TWELVE SCREWS (3). Install using
ly enough pressure to pre-
cross tip screwdriver (4).
vent hoses from slipping.
1
SIX HOSES (1) WITH SIX MALE
HOSE FITTINGS (2). Install on ac-
cumulator assembly (3) using 7/16-in.
open end wrench (4) and slip joint
pliers (5).
2
ACCUMULATOR ASSEMBLY (3).
a. Position against plate (6).
b. Install two screws (7), two wash-
ers (8), and two nuts (9) using
two 7/16-in. open end wrenches
(10).
4-52