TM 9-4910-387-14-2
lead to LUBE HEAT switch contact (3) and the
other lead to LUBE HEAT switch contact (2).
3. Check for continuity. If continuity is not present,
4. If LUBE HEAT light does not light, proceed to
step C.
C. THERMOSTAT FOR LUBE OIL TANK ASSEMBLY MAY BE DEFECTIVE.
NOTE
thermostat, go from pins Y and Z of
male connector plug.
1. Remove terminal box cover from lube oil tank
contact (1) and the other lead to tank heater
contact (2).
3. Resistance should be indicated. If resistance is
4. If LUBE HEAT light does not light, proceed to
step D.
6-57