TM 9-4935-481-14-1
C3
Table 3-11. DMS-D Performance Test-Continued
Table 3-11. DMS-D Performance Test-Continued
STEP
UNIT
PROCEDURE CORRECTIVE ACTION
STEP
UNIT
PROCEDURE CORRECTIVE ACTION
Record the DMM reading in steps 657, 658 and 659 for use in steps 660 and 661.
664
PPE
Momentarily actuate TEST START switch.
665
ITP
Set INTERNAL TEST switch to the positions indicated. Then set
CIP
INTERNAL TEST
COUNTER INHIBIT(SEC)
Reading
DMM
RUN/HOLD/OFF switch to HOLD, the COUNTER INHIBIT(SEC) dial to the
654
1
00.35
+0.4730 to +0.4770 Vdc
positions indicated, the RUN/HOLD/OFF switch to RUN and observe
the DMM reading for each series of switch settings. Record
655
(86)
+0.5220 to +0.5280 Vdc
the DMM reading in steps 669, 670, and 671 for use in steps
672 and 673.
655
00.36
+0.5220 to +0.5280 Vdc
INTERNAL TEST
COUNTER INHIBIT(SEC)
Reading
(87)
666
1
00.64
-0.4730 to -0.4770 Vdc.
656
00.99
+0.5220 to +0.5280 Vdc
(109)
(87)
667
00.65
-0.5220 to -0.5280 Vdc.
657
01.01
+0.7620 to +0.7700 Vdc
(89)
(88)
668
00.99
-0.5220 to -0.5280 Vdc
(89)
658
2
Record reading
669
01.01
-0.7620 to -0.7700 Vdc.
659
3
Record reading
(90)
660
Compute the difference between step 657 and 658. The difference
Record reading.
shall be 0.6123 to 0.6317 Vdc.
(107)
670
2
Record reading.
671
3
Record reading.
661
Compute the difference between step 657 and 659. The difference
shall be 0.6123 to 0.6317 Vdc.
672
Compute the difference between step 669 and 670. The difference
(108)
shall be 0.1113 to 0.1207 Vdc.
(91)
662
PPE
SEQUENCE switch to AUTO 3.
673
Compute the difference between step 669 and 671. The difference
663
CIP
COUNTER INHIBIT(SEC) dial to 00.63.
shall be 0.1113 to 0.1207 Vdc.
3-100