TM9-4935-481-14-1
C3
Table 3-11. DMS-D Performance Test-Continued
Table 3-11. DMS-D Performance Test-Continued
STEP
UNIT
PROCEDURE
CORRECTIVE ACTION
STEP
UNIT
PROCEDURE
CORRECTIVE ACTION
727
Compute the difference between step 723 and 725. The difference shall be 0.1113 to 0.1207 Vdc.
the positions indicated, the RUN/HOLD/OFF switch to RUN wait for
Replace card A5. Check A5 pins
INHIB lamp to illuminate, then observe the DMM reading for each
40, 103, and 111.
series of switch settings. Record the DMM reading in steps 723,
728
PPE
SEQUENCE switch to AUTO 10.
724, and 725 for use in steps 726 and 727.
729
CIP
COUNTER INHIBIT(SEC) dial to 00.64.
730
PPE
Momentarily actuate TEST START switch.
731
ITP
Set INTERNAL TEST switch to the positions indicated. Then set
INTERNAL TEST
COUNTER INHIBIT(SEC)
Reading
CIP
RUN/HOLD/OFF switch to HOLD, the COUNTER INHIBIT(SEC) dial to
718
1
00.64
-0.0050 to +0.0050 Vdc
DMM
the positions indicated, the RUN/HOLD/OFF switch to RUN and
(92)
observe the DMM reading for each series of switch settings.
Record the DMM reading in steps 735, 736 and 737 for use in
719
00.65
+3.403 to +3.437 Vdc
steps 738 and 739.
(98)
INTERNAL TEST
COUNTER INHIBIT(SEC)
Reading
720
16.99
+3.403 to +3.437 Vdc
(98)
732
1
00.65
-0.0050 to +0.0050 Vdc
721
17.01
+3.863 to +3.901 Vdc
(92)
(99)
733
00.66
-0.5220 to -0.5280 Vdc
722
18.39
+3.863 to +3.901 Vdc
(89)
(99)
734
00.99
-0.5220 to -0.5280 Vdc
723
18.41
+3.403 to +3.437 Vdc
(89)
(98)
Record reading.
735
1.01
+3.204 to +3.236 Vdc
724
2
Record reading.
(100)
Record reading.
725
3
Record reading.
726
Compute the difference between step 723 and 724. The difference shall be 0.1113 to 0.1207 Vdc.
(91)
3-103