TM 9-4935-481-14-1
C3
Table 3-11. DMS-D Performance Test-Continued
Table 3-11. DMS-D Performance Test-Continued
STEP
UNIT
PROCEDURE
CORRECTIVE ACTION
STEP
UNIT
PROCEDURE
CORRECTIVE ACTION
761
Compute the difference between step 758 and 759. The difference
shall be 0.0519 to 0.0601 Vdc.
INTERNAL TEST
COUNTER INHIBIT(SEC)
Reading
(102)
770
18.41
+4.975 to +5.025 Vdc
Record reading.
762
Compute the difference between step 758 and 760. The difference
shall be 0.0519 to 0.0601 Vdc.
771
2
Record reading.
Replace card A5. Check A5 pins
772
3
Record reading.
40, 103, and 111.
773
Compute the difference between step 770 and 771. The difference
763
PPE
SEQUENCE switch to AUTO 13.
shall be 0.6915 to 0.7125 Vdc.
764
CIP
COUNTER INHIBIT(SEC) dial to 16.98.
(104)
765
PPE
Momentarily actuate TEST START switch.
766
ITP
Set INTERNAL TEST switch to the positions indicated. Then set
774
Compute the difference between step 770 and 772. The difference
CIP
RUN/HOLD/OFF switch to HOLD, COUNTER INHIBIT(SEC) dial to
shall be 0.6915 to 0.7125 Vdc.
DMM
the positions indicated, the RUN/HOLD/OFF switch to RUN wait
for the INHIBIT lamp to illuminate then observe the DMM reading
Replace card A5. Check A5 pins
for each series of switch settings. Record the DMM reading in
50, 103, and 111.
steps 770, 771, and 772 for use in steps 773 and 774.
775
PPE
SEQUENCE switch to AUTO 16.
INTERNAL TEST
COUNTER INHIBIT(SEC)
Reading
776
CIP
RUN/HOLD/OFF switch to OFF.
767
1
16.99
+4.975 to +5.025 Vdc
777
ITP
INTERNAL TEST switch to 1.
(106)
778
DMM
Observe a reading of +3.403 to +3.437 Vdc. Record for use in steps 781 and 784.
(98)
768
17.01
+4.154 to +4.196 Vdc
(103)
779
ITP
INTERNAL TEST switch to 2.
780
DMM
Record the reading for use in step 781.
769
18.39
+4.154 to +4.196 Vdc
781
Compute the difference between step 778 and 780. The difference shall be 0.1113 to 0.1207 Vdc.
(103)
3-105