C4
TM9-4935-481-14-1
Table 3-11. DMS-D Performance Test-Continued
Table 3-11. DMS-D Performance Test-Continued
STEP
UNIT
PROCEDURE
CORRECTIVE ACTION
STEP
UNIT
PROCEDURE
CORRECTIVE ACTION
1692
CIP
Observe INHIB lamp illuminated before continuing.
1713
CIP
Observe INHIB lamp illuminated before continuing.
1693
TP
Observe GO lamp extinguished and NO GO lamp illuminated.
1714
TP
Observe GO lamp extinguished and NO GO lamp illuminated.
1694
CIP
COUNTER INHIBIT(SEC) dial to 10.11.
1715
CIP
COUNTER INHIBIT(SEC) dial to 00.2.1
1695
MCP
DMM INPUT switch to DMM INPUT.
1715.1
Disconnect 1W20 P2 from J13.
1696
MCP
SELECTOR A switch to D24.
1716
MCP
SELECTOR A switch to F1.
1697
VWS
Adjust AMPTD(VOLTS) control to +0.406 0.0020 Vdc.
0
1717
MCP
SELECTOR B switch to G21.
DMM
1717.1
Connect 1W20 P2 to J13.
1698
MCP
DMM INPUT switch to SEL A.
1718
TP
MODE switch to UP/DN.
1699
TPS
Adjust AMPTD(VOLTS) dial to -0.4791 0.0002 Vdc.
1719
MCP
Remove the white probe from pin "H" of the adapter at J5 and
DMM
connect it to pin "GG" of the same adapter.
1700
TP
Momentarily actuate TEST START switch.
1720
MCP
Adjust COMPARATOR THRESHOLD B control to -4.000 0.0050 Vdc.
1701
CIP
Observe INHIB lamp illuminated before continuing.
DMM
1702
TP
Observe GO and NO GO lamps illuminated.
1721
MCP
DMM INPUT switch to DMM INPUT.
1703
TPS
Adjust AMPTD(VOLTS) dial to -0.4872 0.0002 Vdc.
1722
VWS
Adjust AMPTD(VOLTS) control to +7.890 0.0010 Vdc.
DMM
DMM
1704
TP
Momentarily actuate TEST START switch.
1723
TP
Momentarily actuate TEST START witch.
s
1705
CIP
Observe INHIB lamp illuminated before continuing.
1724
CIP
Observe INHIB lamp illuminated before continuing.
1706
TP
Observe GO lamp extinguished and NO GO lamp illuminated.
1725
TP
Observe GO lamp illuminated and NO GO lamp extinguished.
1707
TPS
Adjust AMPTD(VOLTS) dial to -0.3329 0.0002 Vdc.
(171)
DMM
1708
TP
Momentarily actuate TEST START switch.
1726
VWS
Adjust AMPTD(VOLTS) control to +8.040 0.0010 Vdc.
1709
CIP
Observe INHIB lamp illuminated before continuing
1727
TP
Momentarily actuate TEST START switch.
1710
TP
Observe GO and NO GO lamps illuminated.
1728
CIP
Observe INHIB lamp illuminated before continuing.
1711
TPS
Adjust AMPTD(VOLTS) dial to -0.3248 0.0002 Vdc.
1729
TP
Observe GO lamp extinguished and NO GO lamp illuminated,
DMM
(171)
1712
TP
Momentarily actuate TEST START switch.
1730
VWS
Adjust AMPTD(VOLTS) control to +7.110 0.0010 Vdc.
DMM
3-136