the equipment and convenience recep-
terminals for the AN/MSC-32 components
a r e provided inside the S-184/MSC-32.
tacles is distributed through the pow-
e r duct from circuit breaker switches
CB1 through CB6. Lamp DS7 is con-
n e c t e d across the ac input lines to
a c input circuit after MAIN circuit
C B 7 , and lights when power is ap-
b r e a k e r switch CB7. It indicates the
plied to the AN/MSC-32. Lamps
voltage applied from the power
DS1 through DS6 are connected
source to the AN/MSC-32.
across the circuits controlled by CB1
t h r o u g h CB6, respectively, and light
(2) A m m e t e r M2 is connected to the ac
i n d i v i d u a l l y as each circuit breaker
i n p u t circuit through current trans-
switch is operated to ON.
f o r m e r T1. It indicates the total cur-
b. Grounding. The AN/MSC-32 is grounded
rent being drawn by the operating
t o reduce electrical shock hazards. Ground
c o m p o n e n t s of the AN/MSC-32.