SHIPMENT AND LIMITED STORAGE AND DEMOLITION
TO PREVENT ENEMY USE
Section I. SHIPMENT AND LIMITED STORAGE
(2) Disconnect the power cable connector
57. Disassembly of
Equipment
from the power cable stub connector.
Perform the following procedures when the
Replace both connector covers.
A N / M S C - 3 2 is moved to a different location
or placed in storage.
from the commercial source and store
a. Operate all ac power switches and circuit
it in a storage cabinet.
b r e a k e r switches to their OFF positions ex-
j. D i s c o n n e c t t h e p o w e r c a b l e f r o m t h e I N
cept the LIGHT 1 and LIGHT 2 switches,
POWER 115V AC receptacle in the power and
circuit breaker switch 1 LIGHTS, and the
signal entrance box and replace the covers on
M A I N circuit breaker switch.
the receptacle and connector.
b. Remove the batteries from the TA-312/
k. D i s c o n n e c t t h e g r o u n d s t r a p f r o m t h e
PT, the SB-22 ( * ) /PT, and the hand lantern
G R O U N D TERMINAL in the power and sig-
f o r prolonged storage or long-distance ship-
n a l entrance box. Close and secure the cover
ment.
on the power and signal entrance box.
c. S e c u r e a l l c o m p o n e n t s i n t h e i r c a s e s ,
1. Store the round strap in a storage
m o u n t i n g s , or holders.
cabinet.
m. Close and secure the covers on the ex-
d. Place all miscellaneous items in the stor-
haust blower vents and on the air filter.
age drawers and cabinets, and secure the
n . Remove the ground rod and store it in
d r a w e r s and cabinets for transit.
e. D i s c o n n e c t t h e f i e l d w i r e s f r o m t h e
o. W i n d t h e p o w e r c a b l e a n d t h e C X
P H O N E and INTERCOM binding posts in the
4566/G on the cable reels and secure the reels
p o w e r and signal entrance box (fig. 8) and
to the floor of the shelter (fig. 15).
from the binding posts in the binding post
p. Recheck the area for any loose items.
Be sure all items are properly stored in the
f. Disconnect the 26-pair cable at the power
shelter.
and signal entrance box and replace the covers
q. Clean the shelter thoroughly and check
t o see that the drain plug (fig. 15) is firmly
g. O p e r a t e t h e L I G H T 1 a n d L I G H T 2
in place.
s w i t c h e s , circuit breaker switch 1 LIGHTS,
r. Close and lock the shelter door.
a n d the MAIN circuit breaker switch to OFF.
h. If power was obtained from an adjacent
shelter, disconnect the AN/MSC-32 power
The AN/MSC-32 can be transported by
c a b l e from the OUT POWER 115V AC re-
c e p t a c l e at the adjacent shelter. Replace the
for lifting, loading, and unloading instructions.
r e c e p t a c l e and connector cover.
Caution: When transporting the AN/MSC-
i. If power was obtained from a commer-
32 by air, the outside vent covers of the shel-
cial source, proceed as follows:
ter must be opened to equalize the pressure
inside and outside the shelter.
(1) Turn off or disconnect the power.