TM 5-2420-230-10
Hydraulic fluid (Dexron III) is TOXIC. Wear protective goggles and gloves; use only in
well-ventilated area; avoid contact with skin, eyes, and clothes. Skin and clothing that come in contact
with hydraulic oil should be washed immediately. Saturated clothing should be removed immediately.
Failure to comply may result in injury to personnel.
Cleanliness is essential for correct and safe operation of the hydraulic system. Ensure dirt and debris
are not allowed to enter hydraulic system. Failure to comply may result in damage to equipment.
(8)
Using a clean rag, wipe down hydraulic quick-release couplings (13) and (14) and auxiliary quick-release
couplings (6) and (7).
(9)
Disconnect hydraulic quick-release couplings (13) and (14) from auxiliary quick-release couplings (6) and (7).
(10) Connect quick-release couplings (13) and (14) together.
(11) Push 4-in-1 bucket hoses (10) and (11) through quick-hitch (12).
(12) Using a clean rag, wipe down hydraulic quick-release couplings (4) and (5).
(13) Remove cap (8) and plug (9) from hydraulic quick-release couplings (4) and (5), and connect couplings to
auxiliary quick-release couplings (6) and (7). Connect cap and plug together.
NOTE
Using a clean rag only, wipe hose reel
assembly prior to installing cover.
(14) Remove cover (2) from cab, hold hydraulic
reel (3), and install cover (2) on hose reel.
Change 1