TM 5-2420-230-10
Hydraulic fluid (Dexron III) is TOXIC. Wear
protective goggles and gloves; use only in
well-ventilated area; avoid contact with skin,
eyes, and clothes. Skin and clothing that
come in contact with hydraulic oil should be
washed immediately. Saturated clothing
should be removed immediately. Failure to
comply may result in injury to personnel
Cleanliness is essential for correct and safe
operation of the hydraulic system. Ensure
dirt and debris are not allowed to enter
hydraulic system. Failure to comply may
result in damage to equipment.
(7)
Using a clean rag, wipe down hydraulic
quick-release couplings (4) and (5) and
auxiliary quick-release couplings (6) and (7).
(8)
Disconnect hydraulic quick-release
couplings (4) and (5) from auxiliary
quick-release couplings (6) and (7).
NOTE
Hose quick-release couplings can only be
connected one way.
(9)
Install cap (8) and plug (9) on quick-release
couplings (4) and (5), and pull 4-in-1 bucket
hoses (10) and (11) through quick-hitch (12)
and lay over front of 4-in-1 bucket (1).
(10) Using a clean rag, clean and disconnect
hydraulic quick-release couplings (13)
and (14).
(11) Connect hydraulic quick-release couplings
(13) and (14) to auxiliary quick-release
couplings (6) and (7).
Change 1