TM 55-1925-284-14&P
0022 00
1
6
9
3
12
15
0
2
Figure 1. Blower Relief Valve
INSTALLATION
WARNING
Removing components by means of wire brushing produces flying particles. These
particles can cause serious injury to personnel. Protective goggles, gloves, and
long sleeves must be worn at all times during wire brushing operations. Failure
to comply with this warning can result in serious injury to personnel.
1. Clean the male threads of the relief valve (figure 1, item 1) with a wire brush.
2. Apply antiseizing tape to the male threads of the relief valve (figure 1, item 1).
3. Remove the cover or plug from the MSD open piping.
4. Install the relief valve (figure 1, item 1) into the 90o elbow (figure 1, item 2).
5. Remove the lockouts and tagouts (FM 55-502).
0022 00-2