3-21. WATER TEMPERATURE GAGE.
This task covers:
a.
Removal
b.
Inspection
c.
Installation
SET-UP:
Tools Required:
Tool Kit, General Mechanic's
Materials Required:
Washer, Lock P/N 120217
Equipment Conditions:
(1) Disconnect tube (4) from water manifold.
(2) Remove four nuts (1), two lockwashers (2), and gage (3). Remove tube (4) from gage (3).
b. Inspection.
(1) Inspect gage for broken lens or damage to dial.
(2) Inspect tube for kinks or other damage.
c. Installation.
(1) Connect tube (4) to gage (3).
(2) Inspect gage (3) into instrument panel and secure with two lockwashers (2) and four nuts (1).
(3) Connect tube (4) to water manifold.
3-48