TM 9-2330-227-14&P
CONNECTOR RECEPTACLE REPAIR, 24-VOLT - CONTINUED
ACTION
ITEM
REMARKS
LOCATION
REPAIR - CONTINUED
b. Using soldering iron, heat insert (1)
3. Continued
and pull from wires (2).
12 wires (2)
Pull out.
4. Bushing (3) and
retaining nut (4)
a. Position wires in bushing according
12 wires (2)
5. Bushing (3)
to chart (5).
b. Push all the way through.
c. Using wire stripper, strip insulation
back 1/4-inch.
Slip an insert over each wire, and solder
12 inserts (1)
6. 12 wires (2)
using non-acid solder and soldering iron.
NOTE
Make sure wire ends are clean before soldering, If necessary, clean with cleaning
solvent and stiff fiber brush. Solder must be non-acid type; use rosin flux. Wires
and soldering iron must be pre-tinned for good connection and maximum transfer of
heat. After soldering, clean all solder joints with an acid swabbing brush and alcohol.
Push wire and inserts into bushing
12 wires (2)
7. Bushing (3)
and inserts (1)
until inserts are seated.
Put in place.
Bushing (3)
8. Shell (6)
Bushing retaining
Screw on, and tighten.
9.
nut (4)