TM 9-2330-356-14
Table 3-2. Operator/Crew Troubleshooting (Con`t),
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
FUELING OPERATIONS (Con't)
18. FUEL DOES NOT FLOW DURING ANY OVERWING FUELING OPERATION (M970 and M970A1) (Con't).
Step 3.
Check for clogged screen in nozzle (para 3-1 5).
Clean or replace screen.
19. FUEL DOES NOT FLOW DURING ANY UNDERWING FUELING OPERATION (M970 and M970A1).
Step 1.
Complete Steps 1 through 5 under Malfunction 17, FUEL DOES NOT FLOW DUR/NG ANY FILTERED
FUELING OPERATION.
Check if deadman actuator was not depressed or is inoperable.
Step 2.
NOTE
Connect towing vehicle to build up air pressure. Deadman will not function without outside air
source.
a. Depress deadman actuator S to resume flow to meter.
b. Check deadman hoses for kinks, Straighten kinks.
c. Check deadman hoses for breaks or loose connections. Notify unit maintenance if any
are found.
Step 3.
Clean or replace screen.
Section IV. MAINTENANCE PROCEDURES
Dirt, combined with electrolyte or moisture on top of
General
battery, can result in a continuous battery discharge.
This section provides maintenance instructions for those
items which are the responsibility of the operator/crew,
Inspection Steps and Services.
a.
The maintenance functions are limited to those
operations that are authorized by the Maintenance
(1) Remove the two wingnuts and washers
Allocation Chart (MAC), Appendix B of this manual.
(fig. 3-22) that secure the battery cover to
the battery hold
down bracket. Remove the battery cover.
Batteries, Terminals, and Cables
(2) Inspect battery area for excessive dirt and
The battery terminals and cables should be inspected for
corrosion. Clean battery area using instructions in b
excessive dirt and corrosion, loose connections, and
below.
damage each time before the vehicle is put into operation.