TM 9-2330-356-14
(2) Remove four flat head screws securing
(7) Remove the two screws (9) from the retainer
plate. Position gasket (4) and retainer plate (5) onto
adapter ring.
counter baseplate (1), and attach with two screws (9).
(8) Install snap ring (8) onto the shaft.
(3) Remove four filister head screws and lift off
calibration section along with the bottom rubber gasket.
gasket over the counter base plate (1, fig. 8-11). Fasten the
(10) Attach adapter ring @g. 8-10) to the
(11) Position register (fig. 8-9) onto adapter plate
and secure with four capscrews. Install new security wire.
drive shaft. Remove two screws (9) and insert them into
the two tapped holes in the retainer plate (5). The two
screws will lift the retainer plate from the counter base
plate (1), exposing O-ring (3).
(5) Remove O-ring (3) and replace.
(6) If shims (6) and washers (7) were dislodged
from retainer plate (5), install them into the retainer
plate.
Section V. EMERGENCY VALVE VENT AND FLOAT ASSEMBLY
Emergency Valve Vent
(2) Remove manhole cover to aid in removal of
a.
General. The emergency valve vent is attached to
the top of the tank near the manhole cover. It is connected
WARNING
Ladder has narrow tread. Use care when climbing.
Before the vent can be removed or adjusted, the fuel must
be completely drained from the semitrailer tank and the
NOTE
interior of the tank must be purged. For draining and
purging instructions, refer to Section XX, Chapter 4.
When vent is being removed the connector
and tube will separate from the vent. Hold the
b.
tube while the vent is being removed to keep
it from falling Into tank, then remove the tube.
(1) Make sure emergency valve is closed.
(3) Remove eight capscrews that fasten the vent
to the top of the tank. Remove the vent and gasket.
* U.S. GOVERNMENT PRINTING OFFICE: 1992 643-016/60119
Change 1
PIN:
045819-000