TM9-2330-358-14&P
WARNING
Dry cleaning solvent (PD-680) is both toxic and
flammable. Avoid prolonged breathing of vapors. Avoid
skin contact. Use only in a well ventilated area.
Keep away from open flame. Flash point of solvent is
138F (59C).
b. If any exterior parts are coated with rust preventive compound, remove it
with cleaning solvent (PD-680).
c. Read and follow all instructions contained in DD Form 1397, which is attached
to a conspicuous part of the semitrailer.
d. Inspect equipment for damage incurred during shipping. If equipment has been
damaged, report the damage on DD Form 6, Packing Improvement Report.
e. Check the equipment against the packing slip to see if the shipment is
complete. Report all discrepancies in accordance with DA Pam 738-750.
4-11.
SERVICING THE EQUIPMENT
a. Perform the preventive maintenance checks and services contained in tables
b. Lubricate all points as shown in the lubrication chart (fig. 3-1), regardless
of interval.
c. Schedule the next preventive maintenance checks and services on DD Form 314,
Preventive Maintenance Schedule and Record.
Section IV. ORGANIZATIONAL PREVENTIVE MAITENANCE CHECKS AND SERVICES (PMCS)
Page
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-6
Organizational Preventive Maintenance Checks and Services . . . . . . . . . . . . . . . . . . . . 4-6
PMCS Column Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-8
4-12. GENERAL
To ensure that the semitrailer is ready for operation at all times, it must be
inspected systematically so that defects may be discovered and corrected before they
result in serious damage or failure. Table 4-1 contains a tabulated listing of
preventive maintenance checks and services to be performed by Organizational
Maintenance personnel. All deficiencies and shortcomings will be recorded as well
as the corrective action taken on DA Form 2404 at the earliest possible opportunity.
4-13.
0RGANIZATIONAL PREVENTIVE MAINTENANCB CHECKS AND SERVICES
a. The item numbers of table 4-1 indicate the sequence of PMCS.
Perform at
intervals shown below:
(1) DO your (Q) PREVENTIVE MAINTENANCE once every 3 months.
(2) Do your (S) PREVENTIVE MAINTENANCE once every 6 months.
4-6