TM 9-2330-371-14&P
WIRE CONNECTOR - CONTINUED
ACTION
ITEM
LOCATION
REMARKS
FEMALE CONNECTOR REPAIR
Connector halves
11.
Wire lead (7)
Separate halves.
(5 and 6)
12.
Shell (8)
Connector
Slide up wire lead (7) until clear of
half (6)
terminal (9) .
Using cutting pliers, cut off
Wire lead (7)
13.
terminal (9).
Be sure to leave enough lead for
connection after repair.
Shell (8) and
Slide off wire lead (7).
14.
Wire lead (7)
sleeve (10)
Discard shell (8) and sleeve (10).
a. Using wire stripper, strip insulation
15.
Wire lead (7),
1/8-inch (3.18 mm) from end.
shell (8) and
b. Slide on new shell (8) and sleeve
sleeve (10)
(10), and apply insulating compound
to wire end lead (7).
New terminal (9)
16.
Slide onto wire lead (7) and crimp end
using crimping tool.
Slide down over terminal (9) until seated.
Shell (8) and
17.
Be careful not to dislodge
sleeve (10)
spring (11).
Connector halves
Apply insulating compound to outside of
18.
(5 and 6)
female connector half (6) and push together
until seated.
Semitrailer lights
Apply power, turn on, and check operation
19.