TM 9-2350-222-10-2
OPERATE MOLDBOARD (STOW MOLDBOARD IN EMERGENCY) - Continued
CAUTION
When lifting moldboard with emergency lift
cables, always place BULLDOZER CONTROL
VALVE lever (L) in FLOAT position or damage to
equipment will occur.
10. Set SELECTOR VALVE lever (M) to Hull.
11. Move BULLDOZER CONTROL VALVE lever (L) to FLOAT
position.
WARNING
Always use a ground guide when driving vehicle
in reverse. Crewmember on ground will ground
guide driver. Failure to use a ground guide
could result in injury or death to ground
personnel. Keep ground crew at least 15 feet
away from vehicle until moldboard (D) is locked
in stowed position and tension is removed from
lift cables. Cable could break and injure ground
crew.
12.
13.
Press and hold brake pedal (N).
14.
Shift transmission shift lever (P) to R (reverse).
15.
Drive vehicle slowly in reverse until moldboard (D) is raised to
its maximum height.
16. When moldboard (D) reaches its maximum height, press and
TA132405
hold brake pedal (N).
2-265