TM 9-2350-222-10-2
OPERATE MOLDBOARD (STOW MOLDBOARD IN EMERGENCY) - Continued
NOTE
Always wear gloves when handling steel cables.
2. Using adjustable wrench (B), loosen nut (E) on eyebolt (F).
3.
Unscrew eyebolt (F). If necessary, insert pinch bar (A) thru
eyebolt (F). Use pinch bar (A) to turn eyebolt.
4. Remove eyebolt (F) and clamp (G). Emergency lift cable (C) will
drop free. Put eyebolt (F) and clamp (G) in right front fender box
to prevent loss.
5. Pull emergency lift cable (C) from retaining bracket (H).
6. Pull emergency lift cable (C) on top of track.
7. Loop emergency lift cable (C) around track end connector (J) that
is located above compensating idler wheel (K).
8. Repeat steps 2 thru 7 on opposite side, then continue with step 9.
TA132404
2-264