TM 9-4110-254-14
(6)
Wrap ant-seize tape around threaded end of elbow (21) Install elbow and two cap and chains (20)
(7)
Wrap anti-seize tape around threaded end of each tee (19) and install two tees
(8)
Aline capillary tubes (17) with tees (19) using tags as reference being careful not to bend or kink tubes.
Tighten six flare nuts (18)
(9)
Install strain relief cable bushing (15) and conduit locknut (16)
(10) Push wire leads (13) through strain relief cable bushing (15). Install wire leads, using tags and wiring
diagram (fig 1-4), and four screws (14). Remove tags.
(11) Install cover (4) and two screws (3).
NOTE
FOLLOW-ON MAINTENANCE
Close both side doors
Close front top door.
5-81