TM 9-4110-255-14
Table 2-1. Operator Preventive Maintenance Checks and Services for Model F5000RD - Continued
Location
Item No.
Interval
Procedure
Not Fully Mission Capable If:
Item to
Check/
Service
4
Before
Inspect pulleys for cracks, chips, or warpage.
Pulley is cracked,
Inspect for secure mounting to shaft.
If damaged chipped, warped, or
or loose, notify unit maintenance to tighten or
loose on shaft.
replace it as necessary.
5
Before
Fan Drive
Inspect fan drive shaft for cracks, chips, or
Fan drive shaft is
Shaft
warpage. If damaged, notify direct support
cracked, chipped, or
maintenance to replace it as necessary.
warped.
WARNING
The fuel used in this refrigeration unit is
highly explosive. Do not make or use
open flame when performing
maintenance. Flames and explosion
could result in severe personal injury or
death.
6
Before
Fuel Tank
Inspect fuel tank.
a.
Check for cuts, dents, cracks, or leaks.
Fuel tank is cut, cracked,
or leak is found.
b.
Service fuel tank by checking fuel level.
If Fuel level is less than 1/4
level is less than 1/4 tank, top off with fuel
tank.
5F (-15C) and 125F (52C) or
0F (-18C) and 5F (-15C).
7
Before
Engine
Inspect engine.
a. Check for fluid leaks.
Any fuel leak or class III
oil fluid leak is found.
b.
Service engine by checking oil level. Oil
Oil level is below the
level is at the lower MINIMUM mark or
lower MINIMUM mark
below on the dipstick. Add oil to second
on the dipstick.
MAXIMUM mark. If temperature is above
1040 F (40C) use (item 12, appendix E), if
temperature is between 5F (-15C) and
104F (40C) use (item 10, appendix E), if
temperature is below 5F (-15C) use
8
Before
Air Cleaner
Inspect for missing or damaged air cleaner and
Damaged or missing air
attaching hardware.
cleaner and attaching
hardware.
2-11