TM 9-4110-255-14
Table 2-1. Operator Preventive Maintenance Checks and Services for Model F5000RD - Continued
Location
Item No.
Interval
Procedure
Not Fully Mission Capable If:
Item to
Check/
Service
26
Weekly
Housing
a.
Inspect the housing for cracks and loose or
missing hardware. If cracked, notify direct
support maintenance for repair. If hardware
is loose or missing, notify unit maintenance
to tighten or replace it as necessary.
b.
Inspect the housing for any chipped or
missing paint and evidence of corrosion. If
paint is damaged or enclosure shows
evidence of corrosion, notify direct support
maintenance to paint it.
c.
Debris or foreign
drain plastic tubing for any debris or foreign
material obstructing the
material obstructing it. Remove any debris
condensate drain
or foreign material from the condensate
opening.
drain tubing. If tubing cannot be cleaned,
notify unit maintenance to clean it.
d.
Inspect for secure mounting to the
Housing is loose on
refrigerator enclosure. If loose, notify unit
refrigerator enclosure.
maintenance to secure it.
e.
Inspect for missing or damaged mounting
Unit mounting bolt is
bolt assembly. If missing or damaged,
damaged or missing.
notify unit maintenance to repair or replace
it.
27
Weekly
Inspect ammeter for cracked or damaged cover
Cover lens damaged to
lens and cracks in case.
interfere with accurate
reading or crack in case.
28
Weekly
Fuel Gage
Inspect fuel gage for cracked or damaged cover
Cover lens damaged to
lens and cracks in case.
interfere with accurate
reading or crack in case.
2-16