TM 9-4110-255-14
4-36. TEMPERATURE SWITCH S3 REPLACEMENT .
This task covers:
a. Removal
b. Installation
INITIAL SETUP
Materials/Parts:
Equipment Conditions:
Marker tags (2)
Refrigeration unit shut down (para 2-7) and battery
Tie Down Straps (2)
Insulation Tape
a. Removal.
(1) Remove insulation (1) as necessary.
(2) Be sure battery has been disconnected, then tag and disconnect two tabs (2).
(3) Cut two tie down straps (3) and remove defrost temperature switch (4).
Figure 4-30. Temperature Switch
4-93