TM 9-4110-255-14
4-35. BATTERY BT TESTING AND REPLACEMENT .-Continued
(9) Remove self locking nut (25), clamp (26), and bolt (27). Discard self locking nut.
(10) Remove ten bolts (28), lock washers (29), and batteryframe (16). Discard lock washers.
c. Installation.
NOTE
Access to battery is best achieved through the top access panel.
(1) If removed, install battery frame (16), ten new lock washers (29), and bolts (28).
(2) Install clamp (26), bolt (27), and new self locking nut (25).
(3) Install two clamps (22), bolts (23), and new self locking nuts (21).
(4) Install differential oil pressure switch (20), two flat washers (19), new lock washers (18), and bolts (17).
WARNING
Battery can explode and cause injury to personnel and equipment if battery is dropped or
punctured. Do not lift battery by terminals.
(5) Position four L-bolts (14) in the battery frame (16). Install battery (6) and shield (13) as noted during
removal.
(6) Install battery clamp (12) over L-bolts (14).
(7) Install four flat washers (11) and new self locking nuts (10).
WARNING
Battery explosion and personal injury can occur if positive lug is not installed first or if battery
posts are shorted.
(8) Install positive lug (8) using tag and wiring diagram (fig. 14) and tighten bolt (9). Cover lug with red
(positive) shield (7). Remove tag.
(9) Install negative lug (4) using tag and wiring diagram (fig. 1-4) and tighten bolt (5). Cover lug with black
(negative) shield (3). Remove tag.
NOTE
FOLLOW-ON MAINTENANCE:
Install top access panel (para 4-13). Close right side door. Put unit back into service.
4-92